Dual SmartPDU 19"-2HE with 2x 8/C13 (IEC60320), 16A (A+B) with RCM

KentixONE LAN (PoE) Sysport (TYPE B) MID approved
Dual SmartPDU with separate A+B feed as a system solution with integrated Kentix MultiSensor technology and 2 height units, RCM and calibrated current measurement. The SmartPDU can be easily managed centrally using the integrated KentixONE software. The electronics of the SmartPDU are supplied via PoE, i.e. in the event of a power failure, both the sensors and the management of the PDU are guaranteed by a UPS-buffered PoE switch. In addition, further digital inputs/outputs are available via the Kentix system port, as well as the option of connecting electronic RFID rack levers directly.

Ideal for IT/OT applications
The Dual SmartPDU are two PDUs in one housing and are therefore particularly cost and space-saving. All the advantages of two separate PDUs with separate power supply and intelligent monitoring are retained.

  • 16xC13 IEC60320 IEC-Lock lockable sockets
  • fuse protection 10A per group (C-type)
  • mains connection 2xC20 (A+B) IEC plug
  • measurement with MID approval
  • Accuracy class B (EN50470-3 MID)
  • two counting ranges
  • display illuminated
  • AC/DC differential current measurement (RCM)
  • climate monitoring (Temp/Hum/Dew)
  • 2-factor early fire detection (ΔT/Tmax, VOC)
  • frequency 45-54Hz (0.01Hz)
  • temperature range 0 to 50°C
  • power supply 230/400VAC
  • connected load 4.6KVA
  • power consumption approx. 5W
  • size (LxWxH) 483x88x88mm
  • protection class IP20

Accessories

IEC-Lock power cable, IEC60320 C19/C13, 16A, 250VAC, BLACK
3m power supply cable BLACK with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.
Size

Price after login/registration

Log in or register now
IEC-Lock power cable, IEC60320 C19/C13, 16A, 250VAC, RED
3m power supply cable RED with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.
Size

Price after login/registration

Log in or register now
IEC-Lock power cable, IEC60320 C14/C13, 10A, 250VAC, BLACK
3m power supply cable BLACK with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.
Size

Price after login/registration

Log in or register now
IEC-Lock power cable, IEC60320 C14/C13, 10A, 250VAC, RED
3m power supply cable RED with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.
Size

Price after login/registration

Log in or register now

Access control for IT/OT rack with monitoring

Wired access control for IT/OT racks protects sensitive technology and data from unauthorized access.

Monitor temperature, humidity and dew point

Monitoring temperature, humidity and dew-point for optimal indoor conditions.

Monitor UPS for status and fault

UPS system monitoring ensures the functionality of the uninterruptible power supply and protects against data loss during power outages.

Measure and monitor power supply in IT/OT rack

The PDU reliably supplies power to devices in IT racks, monitors key parameters including differential current, and ensures environmental monitoring of the rack

Delivery Contents

  • PDU 2HE ready for connection
Note! Please order the correct power cords

Specifications