Extensions at a glance

In addition to the monitoring areas already covered by the MultiSensors, the possibility of connecting external sensors opens up a multitude of further applications. The connection of external units such as air conditioning systems, mains fuse monitoring, UPS systems or general system fault messages are thus possible. In the usual Kentix consistency, our external sensors are either connected plug 'n' play via the Kentix system socket, or via external I/O modules with Ethernet and POE.
Of course, all modules are monitored by KentixONE to prevent failures or sabotage or to report them immediately.

Water leakage sensor for Kentix systemport

SYSPORT
Leakagesensor KLS03 with 10m sensor-cable
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • 5-fold cascadable
  • Monitored for cable break
The leakage sensor is used to detect water leakage on the floor and is connected to an AlarmManager, MultiSensor or a SmartPDU directly to the "Kentix system socket". It continuously detects conductivity via multiple electrodes directly on the housing or additionally via a sensor cable.The sensor has an integrated point sensor with adjustable sensitivity. The versions with sensor cable (KLS03-ROPE-10/20) detect water in addition to the point sensor over the entire sensor cable length (10/20m). The sensitivity of the point sensor is 1-2ml water, the sensitivity of the sensor cable is approx. 10ml water over 20cm cable length.The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.
Sensor cable

Price after login/registration

Log in or register now

How does leakage monitoring work?

The leakage sensor is connected to the systemport (SYSPORT) of a Kentix device and continuously records the conductivity via several electrodes. The connection is made via a standard patch cable and can thus also be easily "patched" into existing cabling.

The leakage sensor also has a 10m or 20m sensor cable whose integrated sensors detect water ingress at an early stage along the entire length of the sensor cable. The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.

I/O expansion modules for external alarms with Ethernet (PoE)

LAN (POE)
Digital I/O-Module with 16-Inputs and Ethernet (PoE)
  • 16 digital inputs
  • connection of external alarm messages
  • Integrated web server
  • Power over ethernet (PoE)
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs for dry-contacts (e.g. air-conditioning, UPS system, external sensors, etc.)
Variation

Price after login/registration

Log in or register now

I/O expansion modules

The I/O expansion modules connect to an AlarmManager-PRO or SiteManager via Ethernet and are used to connect external alarm messages. The communication and power supply is done via Ethernet with PoE. Thus, the module can be mounted anywhere in the local network.

The configuration is done in the KentixONE web interface. The module offers simple IP configuration and testing of the inputs/outputs without additional software via the integrated web server.

Analog expansion module for external signals with Ethernet (PoE)

LAN (POE)
Expansion module with 8 analog inputs and Ethernet (PoE)
  • 8 analoge imputs (0-20V, 4-20mA)
  • For external measured values
  • Integrated web-Server
  • Power over ethernet (PoE)
For connection of analog industrial sensors with 0-10V or 4-20mA signal. Based on these signal interfaces, there is a wide range of individual sensors for almost all applications on the market (gases, fill levels, status values, and many more).The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external measured values to KentixONE. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in KentixONE. 8 analog inputs for measured values Up to 32 modules
Variation

Price after login/registration

Log in or register now
Temperature sensor IP66 (-50 to + 100 ° C) for KIO7017
  • Temperature sensor Pt1000 class B
  • 3 selectable temperature ranges
  • Protection class IP66
  • Temperature sensor with 2m cable length
PT1000 class B outdoor temperature sensor with active current (4-20mA) and voltage output (0-10V).Three selectable temperature ranges (-50°C ... + 50°C; 0°C ... + 50°C; 0°C ... +100°C).Housing protection IP66.Power supply 24VDC/4mA.For connection to I/O module KIO7017.
Design

Price after login/registration

Log in or register now

More sensors for Kentix system port

SYSPORT
Dust-Sensor for detection of surface contamination
  • Detects surface contamination
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • Optical sesnsor
The optical DustSensor is used to detect the degree of contamination in data centers, IT racks and distribution boards.It is connected directly to the Kentix system socket via an RJ45 patch cable (5 m included in delivery).The sensitivity can be adjusted directly on the sensor.

Price after login/registration

Log in or register now
SYSPORT
Magnet Door-Contact, white, 2m cable with RJ45 for Kentix-Systemport
  • Opening detector
  • Connection to system socket
  • Cable length 2m
Door contact for direct connection to Kentix system jack.

Price after login/registration

Log in or register now
SYSPORT
I/O relais adapter for Kentix sytem port
  • I/O adapter
  • 2 digital inputs
  • 2 relay outputs
I/O adapter for connection to Kentix system port for connecting external IN/ OUTPUTS via the system socket2x digital input, 2x relay output

Price after login/registration

Log in or register now