External sensors at a glance

In addition to the monitoring areas already covered by the MultiSensors, the possibility of connecting external sensors opens up a multitude of further applications. The connection of external units such as air conditioning systems, mains fuse monitoring, UPS systems or general system fault messages are thus possible. In the usual Kentix consistency, our external sensors are either connected plug 'n' play via the Kentix system socket, or via external I/O modules with Ethernet and POE.
Of course, all modules are monitored by KentixONE to prevent failures or sabotage or to report them immediately.


I/O expansion modules for AlarmManager and SiteManager (digital)

The I/O expansion modules are used to connect external messages via electrical transfer contacts. This means that, for example, alarm messages from external systems such as generators, UPS systems, air-conditioning systems, etc. can be easily integrated and monitored.

LAN (POE)
Digital I/O-Module with 16-Inputs and Ethernet (PoE)
  • 16 digital inputs
  • connection of external alarm messages
  • Integrated web server
  • Power over Ethernet
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs (e.g. air conditioning, UPS system, external sensors, etc.)Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.

Price after login/registration

Log in or register now
LAN (POE)
Digital I/O-Module with 8-In-/Outputs and Ethernet (PoE)
  • 8 digital in- and outputs
  • connection of external alarm messages
  • Integrated web server
  • Power over Ethernet
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages to KentixONE. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE.8 digital in- and outputs (e.g. air conditioning, UPS system, external sensors, etc.)Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.

Price after login/registration

Log in or register now

I/O expansion

The I/O expansion modules connect to an AlarmManager-PRO or SiteManager via Ethernet and are used to connect external alarm messages. The communication and power supply is done via Ethernet with PoE. Thus, the module can be mounted anywhere in the local network. The configuration is done in the KentixONE web interface. The module offers easy IP configuration and testing of the inputs/outputs without additional software via the integrated web server. Up to 32 modules can be operated e.g. at one AlarmManager-PRO.



I/O expansion modules for AlarmManager and SiteManager (Analogue)

For connecting analogue industrial sensors based on 0-10V or 4-20mA signals. Based on these signal interfaces, there are many individual sensors for almost all applications on the market (gases, fill levels, status values, etc.).

LAN (POE)
Analog-Module with 8-Inputs and 4 digital-outputs and Ethernet (PoE)
  • 8 analog in- and 4 outputs
  • connection of external alarm messages
  • Integrated web server
  • Power over Ethernet
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages to KentixONE. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE.8 anlog inputs and 4 digital outputs (e.g. air conditioning, UPS system, external sensors, etc.)Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.

Price after login/registration

Log in or register now
Outside temperature sensor IP66 (-50 to + 100 ° C) for KIO7017
  • Temperature sensor Pt1000 class B
  • 3 selectable temperature ranges
  • Protection class IP66
  • Temperature sensor with 2m cable length
PT1000 class B outdoor temperature sensor with active current (4-20mA) and voltage output (0-10V).Three selectable temperature ranges (-50°C ... + 50°C; 0°C ... + 50°C; 0°C ... +100°C).Housing protection IP66.Power supply 24VDC/4mA.For connection to I/O module KIO7017.

Price after login/registration

Log in or register now
Cable temperature sensor IP66 (-50 to + 100 ° C) for KIO7017
  • Temperature sensor Pt1000 class B
  • 3 selectable temperature ranges
  • Protection class IP66
  • Temperature sensor with 2m cable length
Sleeve temperature sensor Pt1000 class B with active current (4-20mA) and voltage output (0-10V). Three selectable temperature ranges (-50°C ... + 50°C; 0°C ... + 50°C; 0°C ... +100°C).Housing protection class IP66.Temperature sensor with 2m cable length, sensor sleeve diameter 6mm (V4A).Power supply 24VDC/4mA.For connection to I/O module KIO7017.

Price after login/registration

Log in or register now


Water-liquid sensor for Kentix system port

SYSPORT
Leakagesensor KLS03 with 10m sensor-cable
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • 5-fold cascadable
  • Monitored for cable break
The leakage sensor is used to detect water leakage on the floor and is connected to an AlarmManager, MultiSensor or a SmartPDU directly to the "Kentix system socket". It continuously detects conductivity via multiple electrodes directly on the housing or additionally via a sensor cable.The sensor has an integrated point sensor with adjustable sensitivity. The versions with sensor cable (KLS03-ROPE-10/20) detect water in addition to the point sensor over the entire sensor cable length (10/20m). The sensitivity of the point sensor is 1-2ml water, the sensitivity of the sensor cable is approx. 10ml water over 20cm cable length.The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.
Sensor cable

Price after login/registration

Log in or register now

Water leakage detection

The leakage sensor is connected to the systemport (SYSPORT) of a Kentix device and continuously records the conductivity via several electrodes. The connection is made via a standard patch cable and can thus also be easily "patched" into existing cabling. The leakage sensor ROPE also has a sensor cable whose integrated sensors detect water ingress at an early stage along the entire length of the ROPE cable. The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.

Your personal contact

Do you have questions or need advice on our products? I am at your disposal around the topics access, video and monitoring and look forward to hearing from you.

Miguel Marinho

Miguel Marinho

Inside Sales Manager

info@kentix.com
+49 6781 562510



More sensors for Kentix system port

AlarmManager and almost all MultiSensors are equipped with a Kentix-specific expansion connector with RJ45 socket, the so-called Kentix system port. Additional external sensors or signals can be connected to this without much effort.

SYSPORT
Dust-Sensor for detection of surface contamination
  • Detects surface contamination
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • Optical sesnsor
The optical DustSensor is used to detect the degree of contamination in data centers, IT racks and distribution boards.It is connected directly to the Kentix system socket via an RJ45 patch cable (5 m included in delivery).The sensitivity can be adjusted directly on the sensor.

Price after login/registration

Log in or register now
SYSPORT
Magnet Door-Contact, white, 2m cable with RJ45 for Kentix-Systemport
  • Opening detector
  • Connection to system socket
  • Cable length 2m
Door contact for direct connection to Kentix system jack.

Price after login/registration

Log in or register now
SYSPORT
I/O relais adapter for Kentix sytem port
  • I/O adapter
  • 2 digital inputs
  • 2 relay outputs
I/O adapter for connection to Kentix system port for connecting external IN/ OUTPUTS via the system socket2x digital input, 2x relay output

Price after login/registration

Log in or register now