High availability with Kentix SmartPDUs - Made in Germany

Intelligent, robust and calibrated: That was the formula for the development of our SmartPDU series. Together with long-standing data centre customers, we have developed a PDU that meets the essential requirements of robust and fail-safe power distribution.
We have thus fully concentrated on using the most proven components from the industry of power distribution. The result is an ultra-robust PDU that meets all requirements for power measurement and monitoring and can be managed via state-of-the-art interfaces (SNMPv2/3, REST API).


Dual SmartPDU with 2 x 24 (C13/10A) sockets

Two SmartPDU in one, saves space and cost, the perfect solution for edge applications.
LAN(PoE)
KentixONE
MID-APPROVED
2x7.3kW
NEW
Dual SmartPDU 40U with 2x 24/C13 (IEC60320), 32A (A+B) with RCM
  • Calibrated dual current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.2x 24/C13 IEC sockets IEC lockable (IEC60320)Fuse protection 10A per group (C-type)2x mains connection IEC60309 plug 32A (BLUE) (L1/N/PE/6h)Cable connection 2m H05VV-F (4mm2)Measurement with MID approvalaccuracy class B (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate monitoring (Temp/Hum/Dew)optional early fire detection (CO)network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50°CPower supply 230/400VACConnected load max 2x 7.2KVALine consumption max 40Wsize (LxWxH) 1770x78.1x62.5mmprotection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
MID-APPROVED
2x3.6kW
Dual SmartPDU 40U with 2x 24/C13 (IEC60320), 16A (A+B) with RCM
  • Calibrated dual current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.2x 24/C13 IEC sockets IEC lockable (IEC60320)Fuse protection 10A per group (C-type)2x mains connection IEC60309 plug 16A (BLUE) (L1/N/PE/6h)Cable connection 2m H05VV-F (2.5mm2)Measurement with MID approvalaccuracy class B (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate monitoring (Temp/Hum/Dew)optional early fire detection (CO)network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50°CPower supply 230/400VACConnected load 2x 3.6KVAPower consumption max 40WSize (LxWxH) 1770x78.1x62.5mmProtection class IP20

Price after login/registration

Log in or register now

Individual SmartPDU Projects

Our SmartPDU series is not only based on one of the most flexible software platforms on the market, the hardware can also be customized to your project requirements. We will be happy to show you what is possible.



SmartPDU with 24 x (C13/10A) and 6 x (C19/16A) sockets

LAN(PoE)
KentixONE
MID-APPROVED
11kW
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 16A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC receptacles IEC lockable (IEC60320)Fuse protection 10A/16A per group (C-type)Mains connection IEC60309 plug 16A (RED) (L1/L2/L3/N/PE/6h)Cable connection 3m H05VV-F (2.5mm2)Measurement with MID approvalaccuracy class B (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate monitoring (Temp/Hum/Dew)network connection RJ45 (PoE Ethernet)frequency 45-54Hz (0.01Hz)Temperature range -10 to 50°CPower supply 230/400VACConnected load 11KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62.5mmProtection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
MID-APPROVED
22kW
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC receptacles IEC lockable (IEC60320)Fuse protection 10A/16A per group (C-type)Mains connection IEC60309 plug 32A (RED) (L1/L2/L3/N/PE/6h)Cable connection 3m H05VV-F (6mm2)Measurement with MID approvalaccuracy class B (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate monitoring (Temp/Hum/Dew)network connection RJ45 (PoE Ethernet)frequency 45-54Hz (0.01Hz)Temperature range -10 to 50°CPower supply 230/400VACConnected load 17.9KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62.5mmProtection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
MID-APPROVED
7.3kW
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 1-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC sockets IEC-Lock lockable (IEC60320) protection 10A / 16A per group (C-type)mains connection IEC60309 connector 32A (BLUE) (L/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approvalclass B accuracy (EN50470-3 MID)three counting ranges AC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230/400VACmaximum load 7.3KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
SYSPORT
MID-APPROVED
SWITCHED
22kW
SmartPDU 40U switchable, metered (MID) with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
  • KentixONE already integrated
  • Switchable individual sockets
  • Calibrated total measurement
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration
  • IEC Lock outlets
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC sockets IEC-Lock lockable (IEC60320) and switchedLED per outletprotection 16A per group (C-type)mains connection IEC60309 connector 32A (RED) (L1/L2/L3/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approval, class B accuracy (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230/400VACmaximum load 22KVAPower consumption approx. 10WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now


SmartPDU with 48 x (C13/10A) sockets

LAN(PoE)
KentixONE
MID-APPROVED
11kW
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 16A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.48xC13 IEC sockets IEC-Lock lockable (IEC60320)protection 10A per group (C-type)mains connection IEC60309 connector 16A (RED) (L1/L2/L3/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approvalclass B accuracy (EN50470-3 MID)three counting ranges, display illuminatedAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230/400VACPower consumption 11,0KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
MID-APPROVED
22kW
SmartPDU 40U with 48/C13-0/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.48xC13 IEC sockets IEC-Lock lockable (IEC60320),protection 10A per group (C-type)mains connection IEC60309 connector 32A (RED) (L1/L2/L3/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approvalclass B accuracy (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230/400VACPower consumption 13.8KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
MID-APPROVED
7.3kW
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 1-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.48xC13 IEC sockets IEC-Lock lockable (IEC60320)protection 10A per group (C-type)mains connection IEC60309 connector 32A (BLUE) (L/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approvalclass B accuracy (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230VACPower consumption 22KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now
LAN(PoE)
KentixONE
SYSPORT
MID-APPROVED
SWITCHED
22kW
SmartPDU 40U switchable, metered (MID) with 48/C13 (IEC60320), 3-phase 32A with RCM
  • KentixONE already integrated
  • Switchable individual sockets
  • Calibrated total measurement
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration
  • IEC Lock outlets
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.48xC13 IEC sockets IEC-Lock lockable (IEC60320) and switchedLED per outletprotection 16A per group (C-type)mains connection IEC60309 connector 32A (RED) (L1/L2/L3/N/PE/6h)cable connection 3m H05VV-F (6mm2)measurement with MID approval, class B accuracy (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230/400VACmaximum load 22KVAPower consumption approx. 10WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now


Passive PDU with 24 x (C13/10A) and 6 x (C19/16A) sockets

22kW
Passive PDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 32A
  • IEC Lock connector protection
  • Lockable circuit breakers
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC sockets IEC-Lock lockable (IEC60320)protection 10A / 16A per group (C-type)mains connection IEC60309 connector 32A (RED) (L1/L2/L3/N/PE/6h)cable connection 3m H05VV-F (6mm2)Temperature range -10 to 50 ° CPower supply 230/400VACmaximum load 17.9KVAPower consumption approx. 20W (full-load)Size (LxWxH) 1770x78.1x62. 5mmprotection class IP20

Price after login/registration

Log in or register now

Your personal contact

Do you have questions or need advice on our products? I am at your disposal around the topics access, video and monitoring and look forward to hearing from you.

Michaela Engel

Michaela Engel

Inside Sales Manager

info@kentix.com
+49 6781 562510



Kentix SmartPDU for a secure power-supply in the Data Center

The software integrates all open interfaces for effective management from a single rack to a large data center. All functions are available in the browser via a modern web GUI. KentixONE is license-free and future updates are available free of charge. New software versions can be easily distributed automatically to all clients via the PDU defined as the "main controller". Thanks to SNMP V2/3 and the SNMP MIB Base, which can be easily downloaded from the PDU, integration into existing monitoring systems is very simple. The comprehensive, event-based REST API with so-called web hooks goes one step further. This makes all PDU functions available in encrypted form via SSL/TLS and offers completely new possibilities for effective data center automation. This makes it easy to distribute configurations or templates and service technicians or colocation customers can be guided visually and acoustically to their racks. KentixONE supports Active Directory or LDAP to simplify user management and control of the SmartPDU or connected electronic rack handles via a central directory server.



SmartPDU as system basis for rack monitoring and access control

The DoorLock-RA4 is an important system component with many advantages. In addition to stand-alone use, the lever can also be connected directly to a Kentix SmartPDU. This eliminates the need for wiring between cabinets and provides redundant power to the cabinet's front and rear door handles via the PDUs. The SmartPDU takes over the management of the handle and the monitoring of the door contacts. Only a central AccessManager is then required as further hardware. Integration into an overall Kentix locking system is thus even more easily solved.


More details...