Digital I/O-Module with 16-Inputs and Ethernet (PoE)

The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..
16 digital inputs (e.g. air conditioning, UPS system, external sensors, etc.)

Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.
Connectivity: Ethernet 10/100Mbit and PoE
Funktion: External Alarms
Mounting: DIN Rail
Variant: Extension
de

current93612d0c-59d6-4e5f-bfe9-da1b4674ca92PDF-ExportScroll PDF Exporter


Funktionsbeschreibung

Erweiterungsmodul zum Anschluss an den AlarmManager-PRO.

Das Modul erweitert die externen Ein-Ausgänge des AlarmManagers auf zusätzlich 16 digitale Eingänge. Die Kommunikation erfolgt über Ethernet, somit kann das Modul an beliebiger Stelle montiert werden. Die Konfiguration erfolgt in der Softwareoberfläche des AlarmManager-PRO. Das Modul bietet über den integrierten Web-Server eine einfache IP Konfiguration und den Test der Eingänge ohne zusätzliche Software.

Anschlussmöglichkeit

Externe Alarme von bestehenden Systemkomponenten (Klimageräte, USV-Systeme, Generatoren, Alarmsysteme)

AlarmManager

Anschluss an Kentix AlarmManager-PRO

Konfiguration

Integr. Web-Server (HTTP), Default IP: 192.168.255.1 (Admin/Admin)

Protokolle

KAM-IO Kommunikation über IP-Port: 502 (Default)

Sicherheit

ID, Passwort und IP-Filter

Anschlussklemmen

Steckbare Schraubklemmen für Kabel bis 1mm²

Eingänge

Digitale Eingänge für potentialfreie Beschaltung

ON: Offen

OFF: Eingang nach GND geschaltet

Isolierung

Ethernet 1,5kVDC, I/O 3,7kVrms

Umgebung

Betriebstemperatur 0°C bis +45°C, Rel. Luftfeuchtigkeit 10-90%

Netzwerk

LAN 10/100 Base-TX

Spannungsversorgung

PoE (Class 1) oder externes Netzteil 12-30VDC, 4.3Watt

Gehäuse

72 x 123 x 35 mm (DIN-Schienen Montage)

Lieferumfang

KIO7053, 3m Patchkabel, Power-Anschlusskabel, Anleitung

Zulassung

CE

Zubehör

Netzteil oder PoE-Injektor falls keine PoE Versorgung vorhanden ist.



en

current93612d0c-59d6-4e5f-bfe9-da1b4674ca92PDF-ExportScroll PDF Exporter

Description

Expansion module for connection to the AlarmManager-PRO.

This module extends the external inputs of the AlarmManager by additional 16 digital alarm inputs. Communication via Ethernet, so the module can be mounted anywhere. The configuration is done in the software interface of the AlarmManager-PRO. The module provides a built-in web server for simple IP configuration and testing of the inputs and outputs without any additional software.

Connectivity

External alarms of existing system components (air conditioners, UPS systems, generators, alarm systems)

AlarmManagerConnection to Kentix AlarmManager-PRO

Configuration

Built-in web server (HTTP), Default IP: 192.168.255.1 (Admin/Admin)

Protocols

KAM-IO communication through IP port: 502 (Default)

Security

ID, Password and IP filter

Terminals

Pluggable screw-terminal for cables up to 1mm²

Inputs

Digital inputs for potential-free wiring

ON: Open

OFF: Close to GND

Isolation

Ethernet 1,5kVDC, I/O 3,7kVrms

Environment

Operation temperature 0°C to +45°C, rel. humidity 10-90%

Network

LAN 10/100 Base-TX

Power supply

PoE (Class 1) or external power supply 12-30VDC, 4.3Watt

Chassis

72 x 123 x 35 mm (DIN-rail mounting)

Content of delivery

KIO7053, 3m patch cable, power cable, manual

Approvals

CE

Accessories

Power-supply or PoE injector if no PoE supply is available


  • 1 IO module
  • 1 DIN rail adapter
  • 1 SlimLine cable 3m
LAN (PoE)
FUNK
LTE-4G
KentixONE
AlarmManager-PRO
  • KentixONE already integrated
  • Up to 100 devices (RADIO, LAN)
  • Detected threats: up to 40
  • Web-Server (HTTPS) – KentixONE-GO
  • SMS – E-MAIL – PUSH  - VDS2465
  • LDAP - SNMP - REST-API
  • Room monitoring up to 2.000m²
The AlarmManager is the intelligent alarm control center; here the information of all MultiSensors converges. The AlarmManager is mounted in the server room or rack and forwards all alarm and fault messages to the responsible persons. The configuration is done via a comfortable web interface. All system messages are stored in the internal database.
Color

Price after login/registration

Log in or register now
LAN (PoE)
FUNK
LTE-4G
SYSPORT
KentixONE
StarterSet SmartMonitoring
  • Up to 100 devices (RADIO, LAN)
  • Detected threats: up to 40
  • Web-Server – KentixONE-GO
  • SMS – E-MAIL – PUSH  - VDS2465
  • LDAP - SNMP - REST-API
  • Room monitoring up to 2.000m²
Starter set for rack and room monitoring, expandable for distributed systems, up to 10,000 m²incl. LTE alarm center and integrated web interface / softwareMonitoring of:Temperature, humidity, climate control, smoldering fire / fire / fire gases (CO), intrusion / unauthorized access, access to unauthorized sub-areas (racks/cabinets), line loss / cable defects, failure of active system components, failure of services (HTTP,SMTP,VPN etc.), defective equipment fans, mains voltage failure, UPS defect failure, UPS remaining runtime and capacity.Possibility to connect up to 500 MultiSensors via radio and LANIntegrated LTE modem with slot for SIM card SNMP for integration into monitoring systemsAlarming via eMail (SSL), SMS or SNMP trap
Color

Price after login/registration

Log in or register now
SYSPORT
Magnet Door-Contact, white, 2m cable with RJ45 for Kentix-Systemport
  • Opening detector
  • Connection to system socket
  • Cable length 2m
Door contact for direct connection to Kentix system jack.

Price after login/registration

Log in or register now
LAN (POE)
Digital I/O-Module with 8-In-/Outputs and Ethernet (PoE)
  • 8 digital in- and outputs
  • connection of external alarm messages
  • Integrated web server
  • Power over Ethernet
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages to KentixONE. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE.8 digital in- and outputs (e.g. air conditioning, UPS system, external sensors, etc.)Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.

Price after login/registration

Log in or register now
LAN (POE)
Analog-Module with 8-Inputs and 4 digital-outputs and Ethernet (PoE)
  • 8 analog in- and 4 outputs
  • connection of external alarm messages
  • Integrated web server
  • Power over Ethernet
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages to KentixONE. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE.8 anlog inputs and 4 digital outputs (e.g. air conditioning, UPS system, external sensors, etc.)Up to 32 modules (max. 500 alarm inputs) can be operated on one AlarmManager-PRO.

Price after login/registration

Log in or register now
SYSPORT
I/O relais adapter for Kentix sytem port
  • I/O adapter
  • 2 digital inputs
  • 2 relay outputs
I/O adapter for connection to Kentix system port for connecting external IN/ OUTPUTS via the system socket2x digital input, 2x relay output

Price after login/registration

Log in or register now