Dual SmartPDU 2HE with 2x 8/C13 (IEC60320), 16A (A+B) with RCM

Price on request

Available, delivery time 2-5 Tage

Request an offer
Product number: KPMDU-RC-1600C13C19-2-16-H
EAN: 4260300586918
Weight: 11 kg
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.

  • 16xC13 IEC60320 IEC-Lock lockable sockets
  • fuse protection 10A per group (C-type)
  • mains connection 2xC20 (A+B) IEC plug
  • measurement with MID approval
  • Accuracy class B (EN50470-3 MID)
  • two counting ranges
  • display illuminated
  • AC/DC differential current measurement (RCM)
  • climate monitoring (Temp/Hum/Dew)
  • CO gassensor for early fire detection 20-1.000ppm
  • network connection RJ45 (PoE Ethernet)
  • frequency 45-54Hz (0.01Hz)
  • temperature range -10 to 50°C
  • power supply 230/400VAC
  • connected load 4.6KVA
  • power consumption approx. 3W
  • size (LxWxH) 483x88x88mm
  • protection class IP20
Color: Black
Connectivity: Kentix System Jack RJ45, Ethernet 10/100Mbit and PoE, ModBus TCP
Mounting: 19 inch Mounting
Variant: Stand-Alone
de

current93612d0c-59d6-4e5f-bfe9-da1b4674ca92PDF-ExportScroll PDF Exporter

TypKPMDU-RC-1600C13C19-2–16-H (DUAL PDU)

KPMDU-NC-1600C13C19-1–16-H

Nennleistung, Spannung2x2.3kVA (opt. 2x3.6kVA), 230V

1x2.3kVA (opt. 1x3.6kVA), 230V

Anschlußstecker2x C20 Kaltgerätebuchse (16A) auf Rückseite

2x C20 Kaltgerätebuchse (16A) auf Rückseite

AnschlußkabelAnschlusskabel muss separat bestellt werden

Anschlusskabel muss separat bestellt werden

Steckdosen C13 (IEC60320)18 (2x 9) C13 mit A+B Versorgung

16 (2x 8) C13 mit A+B Versorgung

VerriegelungIEC-LOCK  für C13
Sicherung/Schutzschalter2x 10A C-Typ, verriegelt
Strommessung (geeicht)Integrierte, geeichte Strommessung, Genauigkeit Class B (MID, EN 50470-3)
Minimaler Strom 250mA

Differenzstrommessung (RCM)

OPTIONAL

Integrierte AC/DC
sensitive Di
fferenzstrommessung nach IEC 60664-1
±300mA/100mA (RMS), Genauigkeit <0,2mA
Frequenzbereich DC 0..2kHz
/
Konnektivität
  • Ethernet (10/100MBit)
  • Modbus TCP
Kentix Systembuchse
  • RJ45 mit Kentix spezifischer Belegung für Systemerweiterungen
  • 2 x Digital Input (z.B. Türkontakte, Leckagemelder, ext. Alarme)
  • 2 x Digital Output (z.B. Türschlösser, Signalleuchten)
  • 1 x System BUS
Kommunikation und Sicherheit

HTTPS (Zertifikat), integrierter Web-Server, ReSt-API
Port Sicherheit 802.1x
Protokolle: SNMP V2/3 (GET, TRAP), NTP, SMTP, DHCP

Management

Management Standalone oder Kentix Power-Manager (KPM-100)
Software Deployment (Updates)
Templates für Grenzwerte, Leistungsbereiche

Mess-/Kommunikationsobjekte
  • Spannung (V) L1/L2/Gesamt
  • Strom (A) L1/L2/Gesamt
  • Verbrauch (kWh) L1/L2/Gesamt
  • Wirkleistung (W) L1/L2/Gesamt
  • Scheinleistung (VA) L1/L2/Gesamt
  • Blindleistung (VAR) L1/L2/Gesamt
  • Wirkfaktor (cos phi)
  • Frequenz (Hz)
  • Phasenüberwachung L1/L2/
  • Differenzstrom AC
  • Differenzstrom DC•Sicherungsstatus L1/L2/
  • Temperatur (°C)
  • Relative Luftfeuchte (%)
  • Taupunkt (°C)
  • Vibration (G)
Display (LCD)Beleuchtetes LCD Display (Leistung, Strom, Spannung, Verbrauch)
Optische SignalisierungLED mit ROT/GRÜN (Betrieb, Alarm-/Fehlerzustand)
Akustische Signalisierung
Signalgeber mit 80dB, 2.3kHz (Alarm-/Fehlerzustände)
WerkszustandTaster für Werks-Reset in Seitenwand
GehäuseBlech, Pulverbeschichtet RAL9005
Schutzklasse 1, Schutzart IP20
Größe443 x 88 x 88 mm (BxHxT)
Gewichtca. 3,0kg
Umgebungsbedingungen-10°C bis 55°C, Luftfeuchte 5-95%
Lagertemperatur: -20°C bis 60°C
PrüfungenCE (2014/30/EG, 2014/35/EG, 2011/65/EU)
Elektrische SicherheitDGUV V3 Prüfung, VDE 0105-100
KennzeichnungSeriennummer (Barcode)
Lieferumfang
  • SmartPDU
  • Prüfprotokoll


en

current93612d0c-59d6-4e5f-bfe9-da1b4674ca92PDF-ExportScroll PDF Exporter


TypeKPMDU-RC-1600C13C19-2–16-H (DUAL PDU)KPMDU-NC-1600C13C19-1–16-H
Nominal power, voltage2x2.3kVA (opt. 2x3.6kVA), 230V1x2.3kVA (opt. 1x3.6kVA), 230V
Connector plug2x C20 mains connector (16A) on backside2x C20 mains connector (16A) on backside
Connection cable

Connection cable needs to be ordered separately

Connection cable needs to be ordered separately
Sockets C13 (IEC60320)18 (2x9) C13 with A+B supply16 (2x8) C13 with A+B supply
LockingIEC-LOCK  for C13
Fuse/circuit breaker2x 10A (opt. 16A) C-type, interlocked
Current measurement

Integrated, calibrated current measurement, accuracy class B (MID, EN 50470-3)
Min. current 250mA, max. current 32A

Residual current measurement (RCM)

Optional

Integrated AC/DC sensitive residual current measurement acc. to IEC 60664-1
±300mA/100mA (RMS), accuracy <0.2mA
Frequency range DC 0...2kHz

/
Connectivity

Ethernet (10/100Mbps), PoE
Modbus TCP

Kentix system socket
  • RJ45 with Kentix specific assignment for system extension
  • 2 x digital input (e.g. door contacts, leakage sensor, external alarms)
  • 2 x digital output (e.g. door locks, signal lamps)
  • 1 x System BUS
Communication and security

HTTPS (certificate), integrated web server, ReSt-API
Port security 802.1x
Protocols: SNMP V2/3 (GET, TRAP), NTP, SMTP, DHCP

Management

Management standalone or Kentix PowerManager (KPM-100)
Software deployment (Updates)
Templates for limit values, performance ranges

Measurement and communication objects
  • Voltage (V) L1/L2/L3/total
  • Current (A) L1/L2/L3/total
  • Consumption (kWh) L1/L2/L3/total
  • Active power (W) L1/L2/L3/total
  • Apparent power (VA) L1/L2/L3/total
  • Reactive power (VAR) L1/L2/L3/total
  • Active factor (cos phi)
  • Frequency (Hz)
  • Phase monitoring L1/L2/L3
  • Residual current AC
  • Residual current DC
  • Security status L1/L2/L3
  • Temperature (°C)
  • Relative humidity (%)
  • Dew point (°C)
  • Vibration (G)
Display (LCD)Illuminated LCD display (power, current, voltage, consumption)

Optical signaling

LED red/green (operation, alarm/error states)
Acoustic signalingBuzzer with 80dB, 2.3kHz (alarm/error states)
Factory settingsButton for factory reset in side panel 
Chassis

Sheet metal, powder-coated RAL9005
Appliance class 1, protection class IP20

Dimensions443 x 88 x 88 mm (HxWxD)
Weightca. 3.0kg
Environmental conditions

-10°C to 55°C, humidity 5-95%
Storage temperature: -20°C to 60°C

Approvals

CE (2014/30/EG, 2014/35/EG, 2011/65/EU)

Electrical security

DGUV-V3 test, VDE 0105-100

MarkingSerial number (bar code)
Content of delivery
  • SmartPDU
  • Inspection protocol


  • 1 PDU 2HE ready for connection
  • montage set
Note! Order correct power cord.

Accessories


Accessories

RFID
PIN
Extension reader DoorLock-RA4 Rack-Lift-Handle with PIN RIGHT-TURN (MIFARE® DESFire)
  • Compatible with all cabinet types
  • Extension for KXC-RA4-IP1-R
  • Two-factor authentication
  • RFID - PIN - Smartphone - Smartwatch

Price on request

SYS
Distribution-box for IT-Rack system KXC-RA4 for connection to SmartPDU
  • RA4 distribution box
  • 2 RA4 rack handles
  • For connection SmartPDU

Price on request

IEC-Lock power cable 2m, IEC60320 C14/C13, 10A, 250VAC, RED
2m power supply cable RED with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 3m, IEC60320 C14/C13, 10A, 250VAC, RED
3m power supply cable RED with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 3m, IEC60320 C19/C13, 16A, 250VAC, RED
3m power supply cable RED with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 3m, IEC60320 C19/C13, 16A, 250VAC, BLACK
3m power supply cable BLACK with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 2m, IEC60320 C19/C13, 16A, 250VAC, RED
2m power supply cable RED with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

RFID
PIN
Extension reader DoorLock-RA4 Rack-Lift-Handle with PIN LEFT-TURN (MIFARE® DESFire)
  • Compatible with all cabinet types
  • Extension for KXC-RA4-IP1-R
  • Two-factor authentication
  • RFID - PIN - Smartphone - Smartwatch

Price on request

IEC-Lock power cable 2m, IEC60320 C14/C13, 10A, 250VAC, BLACK
2m power supply cable BLACK with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 3m, IEC60320 C14/C13, 10A, 250VAC, BLACK
3m power supply cable BLACK with IEC60320 C13 to IEC60320 C14 plug, IEC-Lock interlock, cable: H05VV-F 3G1, suitable for devices of protection class I according to IEC61140 Nominal power 10A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

IEC-Lock power cable 2m, IEC60320 C19/C13, 16A, 250VAC, BLACK
2m power supply cable BLACK with IEC60320 C19 to IEC60320 C20 plug, IEC-Lock interlock, cable: H05VV-F 3G1.5, suitable for devices of protection class I according to IEC61140 Nominal power 16A/250VAC at 50/60Hz, -25 to 70°C operating temperature range.

Price on request

Related Products


Related Products

LAN
PoE
API
RCM
Dual SmartPDU 2HE with 2x 8/C13 (IEC60320), 16A (A+B) with RCM
  • Calibrated dual current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID rack lock system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
2PH
Dual SmartPDU 40U with 2x 24/C13 (IEC60320), 16A (A+B) with RCM
  • Calibrated dual current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
2PH
NEW
Dual SmartPDU 40U with 2x 24/C13 (IEC60320), 32A (A+B) with RCM
  • Calibrated dual current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
3PH
SWI
SmartPDU 40U switchable, single metered with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
1PH
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 1-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
2PH
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 16A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
3PH
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 16A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
3PH
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
1PH
SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request

LAN
API
MID
3PH
SmartPDU 40U with 48/C13-0/C19 (IEC60320), 3-phase 32A with RCM
  • Calibrated current measurement
  • RCM differential current measurement
  • Web-GUI, SNMP V2/3, Rest-API
  • RFID Rack locking system connectable
  • IEC Lock connector protection
  • Network management, cascading

Price on request