The Kentix MultiSensor: The revolution in room monitoring

The ingenious Kentix MultiSensors detect up to 20 threats in rooms

The Kentix MultiSensor is the ingeniously simple solution for comprehensive monitoring of IT and technical infrastructures. With just one device, you can monitor your IT rooms for up to 20 physical hazards such as critical climate factors, fire or intrusion and lay the foundation for protection in accordance with BSI basic protection and ISO 27001. 

The MultiSensors are available with Ethernet (PoE) or wireless connection. The network-compatible MultiSensors are also stand-alone capable and can be operated without an additional SiteManager. The MultiSensors with radio are battery-operated. A SiteManager and a network-compatible MultiSensor as a wireless Ethernet gateway are always required for management.

MultiSensors with ethernet (PoE) and radio (BLE)

MultiSensor-LAN with PoE (Black)
KentixONE LAN (PoE) Radio (BLE) Sysport (TYPE A)
  • Integrated sensors: 8
  • Monitored threats: up to 19
  • Web server (HTTPS)
  • E-MAIL - SNMP-V2/3 - REST-API
  • LAN-RADIO (BLE) repeater integrated
MultiSensor for comprehensive room monitoring of up to 20 hazards. Monitors an area of approx. 20-25m². Connection is via Ethernet with PoE (Class 1) and thus requires no further cabling. Operation is possible as a stand-alone sensor with already integrated KentixONE software (HTTPS) or via a networked KentixONE system with AlarmManager or SiteManager. It is mounted on the ceiling using the supplied mounting bracket. Optionally, mounting in the IT rack is also possible with the 19" bracket (accessory).Integrated sensors: temperature, humidity, dew point, carbon monoxide sensor (CO), 360° PIR motion sensor, 3-axis G-sensor, digital input/outputs.Also ideal as an independent room sensor to complement network monitoring systems (PRTG, Nagios, CheckMK, etc) via SNMP-V2/3 or REST API. The sensor can also send alarm email in stand-alone mode.
Color

€525.00 excl. VAT
MultiSensor with Ethernet (PoE) and Thermal-Image
KentixONE LAN (PoE) Radio (BLE) Sysport (TYPE A)
  • Integrated sensors: 9
  • Monitored threats: up to 20
  • 4-factor early fire detection
  • Web server (HTTPS)
  • E-MAIL - SNMP-V2/3 - REST-API
  • LAN-RADIO (BLE) repeater integrated
MultiSensor with integrated 1024px thermal-cam sensor for 4-factor early fire detection and extented environmental monitoring.Full software on board with integrated web server (HTTPS), standalone operation or connection to Kentix AlarmManager-PRODetection angle: 90°Integrated sensors with monitoring of: Temperature, humidity, dew point, smoldering fire (CO),  air quality, air-pressure, motion, acceleration-vibration (G), two external dry-contacts.Alarm notification via e-mail, SNMP traps (V2/3), web-hooks (REsT-API) or via SiteManager SMS and PUSH.
Field of view
Color

€675.00 excl. VAT

Our absolute top sellers, which have already saved many customers from expensive failures. With Ethernet (PoE) connectivity and already integrated KentixONE software, the sensors can also be used stand-alone and easily configured via the web GUI (HTTPS). Thanks to SNMP V2/V3 and REST API, they can be easily integrated into external alarm and monitoring systems at any time.

MultiSensors with radio (BLE)

MultiSensor-ROOM (black) battery powered and wireless
Radio (BLE) Battery
  • Integrated sensors: 6
  • Monitored threats: up to 15
  • Wireless (BLE)
  • Battery (approx. 4 years)
Wireless MultiSensor for ceiling mounting and monitoring of rooms and areas up to approx. 25m². The MultiSensor-ROOM is battery operated and has a long battery life of up to 4 years. It is connected to a MultiSensor LAN via radio (BLE).Integrated sensors for: Temperature, humidity, dew point, early fire detection, motion, vibration/shock.
Color

Price after login/registration

Log in or register now
MultiSensor-DOOR (Black) wireless and battery powered
Radio (BLE) Battery
  • Integrated sensors: 6
  • Monitored threats: up to 10
  • Wireless (BLE)
  • Battery (approx. 4 years)
Ultra-compact MultiSensor for intrusion and status monitoring of doors and windows including ambient monitoring of temperature, humidity and dew point. The sensor is additionally equipped with a 3-axis G-sensor and detects vibration and position changes (sabotage detection, attempted break-in, glass breakage).The MultiSensor-DOOR replaces classic door contacts and can be mounted very easily by gluing or screwing it on. The supplied door/window magnet serves as a counterpart for secure opening detection.The MultiSensor-DOOR is battery operated and has a long battery life (up to four years). It is connected to an MultiSenor-LAN via radio (BLE).
Color

Price after login/registration

Log in or register now

MultiSensor for radio networking with BLE

When it comes to quick and easy integration, the wireless MultiSensors are the first choice. The radio connection (BLE) is made to the MultiSensor-LAN, which acts as a radio network gateway and ensures encrypted and stable radio networking.

The wireless MultiSensors are taught-in to the radio cell of the nearest MultiSensor-LAN and do not require any connections due to battery operation. The sensors are sabotage and battery level monitored.

Expand with external sensors

Leakage sensor for detecting water and flooding
Sysport (TYPE A)
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • 5-fold cascadable
  • Monitored for cable break
The leakage sensor is used to detect water leakage on the floor and is connected to an SiteManager or MultiSensor directly to the Kentix system port (TYP A). It continuously detects conductivity via multiple electrodes directly on the housing or additionally via a sensor cable.The sensor has an integrated point sensor with adjustable sensitivity. The versions with sensor cable (KLS03-ROPE-10/20) detect water in addition to the point sensor over the entire sensor cable length (10/20m). The sensitivity of the point sensor is 1-2ml water, the sensitivity of the sensor cable is approx. 10ml water over 20cm cable length.The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.
Sensor cable

Price after login/registration

Log in or register now
Digital I/O-Module with 16 digital inputs
LAN (PoE)
  • 16 digital inputs (for dry contacts)
  • connection of external alarm messages
  • Integrated web server
  • Ethernet 10/100MBit (PoE)
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs for dry-contacts (e.g. air-conditioning, UPS system, external sensors, etc.)
Variation

Price after login/registration

Log in or register now
I/O relais adapter for Kentix sytem port (Type A)
Sysport (TYPE A)
  • I/O adapter
  • 2 digital inputs
  • 2 relay outputs
I/O adapter for connection to Kentix system port (Type A) for connecting external IN/ OUTPUTS via the system socket.2x digital input, 2x relay output

Price after login/registration

Log in or register now

APP-NOTE #1

Server room up to 20 m² and backup room up to 20 m²

Basic protection monitoring of a typical medium-sized server room with several server racks, UPS system and air conditioning. In addition, there is another room with backup systems, UPS systems or further remote technology.

view

APP-NOTE  #2

Data center with 300 m² and adjoining technical rooms

Data center with a larger number of server racks that need to be monitored for physical hazards such as overtemperature, high humidity, carbon monoxide (early fire detection) and more.

view

APP-NOTE  #3

Distributed infrastructure - Multiple IT rooms spread across sites

IT rooms are distributed over several locations. At each site, there are one or more rooms with server racks, infrastructure and other technology that are to be fully monitored.

view

A success story: German Mining Museum Bochum relies on Kentix SmartMonitoring to monitor exhibits

The museum has been required by the insurance company to safeguard its exhibits with regard to the parameters of temperature and humidity - and to do so in a verifiable manner. In some cases, this also requires leakage monitoring. The museum was already using a monitoring solution from another manufacturer. The original plan was to expand it to meet the new requirements. However, this turned out to be impractical. This would have meant a lot of effort for the cabling and would have caused too high costs overall. The system from Kentix convinced the museum's IT department above all because of its modular design.

German Mining Museum Bochum

Need more information?

Contact us or explore our products in a live demo – free of charge and without obligation.

Miguel Marinho

Inside Sales Manager

Miguel Marinho